Model | 11E | 17E |
No.of Stations | 11 | 17 |
Max Production Capacity(pcs/h) | 16500 | 25500 |
Turret Speed(r/min) | 0-25 | |
Max Pressure(kn) | 80 | |
Max Filling Depth(mm) | 20 | |
Max Tablet Thickness(mm) | 1-8 | |
Max Tablet Diameter(mm) | Ф40 | |
Motor Power(kw) | 3KW/380V,50Hz,Three phase five wire system | |
Overall Size(mm) | 880*750*1600 | |
Machine Weight(kg) | 580 |
If the tablet weight difference is found to increase during tableting (referring to the weight difference of the tablets), exceeding the limit specified in the pharmacopoeia, the reasons and treatment methods are as follows:
① Punch lengths are different, which can easily lead to an increase in tablet weight difference. Therefore, it must be checked with a vernier caliper before use. If the filling position of individual lower punches does not match the filling position, resulting in a reduction in the filling amount of particles, the obstruction should be cleared. .
② The different positions of the hopper will cause differences in its performance, resulting in different falling speeds of particles, resulting in differences in the filling amount of the inner die holes.
③ The particle thickness is different, resulting in different accumulation weights in the feeder. Too much fine powder, excessive particle moisture and insufficient lubricant can cause changes in tablet weight. The particle quality should be improved.
④The reason for the change in tablet weight is generally caused by the malfunction of the tablet press or the negligence of the work. Therefore, during the tablet pressing process, the machine parts should be well maintained, and the machine parts should be inspected in detail for damage, and every Weigh the tablets at regular intervals (10-20 minutes) and make sure the tablets are within the specified weight.